# ICASSP 2027 completion checklist This is an internal execution checklist. It is not part of the submitted PDF. ## Current priority override (2026-09-17) Use the [local-evidence structure decision](../../docs/manuscript_local_evidence_structure_2026-09-17.md) for the current draft. The older semantic/person-grounded checklist below is a conditional extension, not authorization to describe it as implemented or a prerequisite for this narrower activity-anticipation study. - [x] Separate model architecture from streaming inference architecture. - [x] Describe actual G+A fusion, optional pooled vision, and observed-tail recomputation; retain only one displayed method equation. - [x] Move the provisional LLM annotation protocol/workload outside the paper body without relabeling it as human ground truth. - [x] Reserve local-evidence, streaming/context, and combined error/qualitative analysis slots; record pending experiments without LoRA expansion in the [dated log](../../docs/local_evidence_analysis_experiment_log_2026-09-17.md). - [ ] Complete a training-side-frozen A/G/G+A matrix with three seeds and common causal-valid pairs; audit capacity and distinguish their history ranges. - [ ] Evaluate optional vision on/off before retaining a visual-gain claim. - [ ] Complete tail refresh x local-audio four-group comparison with enabled local audio fixed at 5 Hz; report phase strata and same-decomposition replay. - [ ] Re-extract/train the predeclared 4/8/16-s context-cap controls; add G at each cap before claiming local fusion reduces context sensitivity. - [ ] Add a predicted-current-activity persistence reference and capacity/recency controls; do not supply GT activity as model input. - [ ] Report scene-level activity-error counts and fixed-horizon timelines, including a shared failure; semantic negatives cannot override raw labels. - [ ] Report dense AP/mAP and conditional endpoint onset/offset AP separately, including denominators, per-session results, and limits of the three-session official test. Do not claim one-event-one-vote detection. - [ ] Measure full extraction latency/memory before claiming real-time FPS. - [ ] Run paired G/GA backbone-transfer controls for Qwen Omni 3B/7B and MiniCPM-o 4.5 with the same local A; report within-backbone deltas and audit readout, dimensions, refresh, and actual history. MiniCPM 5-Hz rows require GPU tail/cache/causality verification; native 1-Hz pilots need Qwen 1-Hz controls and cannot substitute for matched 5-Hz rows. The dated log overrides the older cache-diagnostic-only scope below, not its safety checks. - [ ] Acknowledge that already viewed Sessions 1--3 results are exploratory; additional seeds do not create a fresh independent test. - [ ] Resolve all TODOs, retain only supported mechanisms, and check the four-technical-page limit, author kit, and IEEE AI-drafting disclosure. ## Reviewer verdict and frozen paper shape The potentially publishable question is: **can a general-purpose Omni readout be adapted into 200 ms, wearer-relative floor control by explicitly preserving short-window causal audio and anonymous visible-person evidence?** The contribution is not “the first audio-visual multiparty turn model.” VAP, EgoSpeak, SICNet, and MuVAP already occupy adjacent territory. The defensible gap is continuous, causal floor-action projection for an invisible camera wearer, combined with a controlled diagnosis of global omni states and a behavior-aligned multi-other event protocol. Current Qwen2.5-Omni-3B results are exploratory motivation only. They neither prove a limitation shared by Omni models nor establish track-consistent fusion as the final method. Qwen2.5-Omni-3B is primary; Qwen2.5-Omni-7B is an optional capacity control. MiniCPM-o remains outside the core method and main comparison; it is permitted only as a diagnostic streaming/cache ablation with a matched Qwen refresh-rate control. The four-page paper has only three contributions: temporal--role adaptation mismatch, one causal local floor adapter, and causal behavioral evidence. LoRA, the oracle, and the event protocol are respectively a baseline, motivation, and validation mechanism. ## P0 — Freeze the task before confirmatory adaptation runs - [ ] Define the exact 5 Hz causal cutoff and physical target interval for each of the ten 0.2 s horizons. - [ ] Freeze wearer-onset/yield and multi-other exchange definitions. - [x] Implement and unit-test competing-risk rules: a response candidate ends before the next other onset and a yield candidate before the next other offset; right-censored and invalid windows are counted explicitly. - [ ] Audit the competing-risk implementation on real timelines and freeze the timeout/source-boundary convention before confirmatory reporting. - [ ] Specify overlap, minimum silence, maximum response delay, duplicate detections, source discontinuities, track visibility, offscreen speakers, and whether target-of-speech strata are diagnostic only. - [ ] Produce train/test event-count tables, duration, class prevalence, and visibility coverage before examining model scores. - [ ] Mark all already viewed Sessions 1–3 results as exploratory. Lock the protocol and select thresholds, checkpoints, and hyperparameters using a training-side fold or cross-fitting over Sessions 4–12. **Gate:** two independent code paths or a manual sample audit must agree on at least 100 randomly selected events. Publish the number of unique other IDs and multi-other opportunity minutes before the main sweep. ## P1 — Audit the primary backbone interface For Qwen2.5-Omni-3B, and for 7B only if used as the scaling control, record: - [ ] exact model/code revision, processor, dtype, and hardware; - [ ] native audio/video sampling and streaming/chunk semantics; - [ ] exact causal hidden-state readout and dimensionality; - [ ] context limit, cache/reset behavior, and source-boundary handling; - [ ] a cutoff/impulse test proving no future frame or sample enters the state; - [ ] P50/P95 latency, throughput, and peak memory. Do not force an offline or future-conditioned feature into the common table. If a model cannot expose a comparable causal state, report that protocol as unsupported. Raw scores are not a pure architecture ranking; emphasize within-backbone deltas. For the diagnostic streaming/cache ablation: - [ ] compare Qwen full causal-prefix recomputation and cache reuse at the same 5-Hz cutoffs, recording numerical agreement, throughput, and memory; - [ ] map the native MiniCPM-o one-second output to 5-Hz rows by causal forward-hold only, never by backfilling the state into earlier rows; - [ ] run a Qwen 1-Hz update-and-hold control with the same physical chunk boundaries and report the within-Qwen 5-Hz versus 1-Hz delta; - [ ] freeze initialization before the first completed chunk and reset every modality/language-model cache at session and source-gap boundaries; - [ ] before admitting a MiniCPM-o 5-Hz cached-branch row, compare it against full causal-prefix recomputation at sampled cutoffs under a frozen cosine and maximum-absolute-error tolerance; - [ ] run future-media intervention tests at every tested cutoff and record throughput, peak memory, feature dimensionality, and exact code revision. If the 5-Hz cached branch fails equivalence or leakage tests, omit that row and report only the native 1-Hz causal-hold diagnostic. Do not present unmatched Qwen--MiniCPM raw scores as a pure backbone comparison. ## P2 — Establish the compact adaptation matrix Run three seeds for the primary backbone with the same data, physical cutoffs, target, prediction-head capacity, optimizer exposure, and evaluator: 1. Frozen global causal state. 2. Pre-registered PEFT/LoRA budget. 3. Global state plus recent local audio. 4. Global state plus pooled local audio and vision. Add a parameter- and history-matched temporal local branch before attributing gain to audiovisual organization. Use the same local adapter for the optional 7B scaling row. **Gate:** baseline standard deviations are known; the evaluator reproduces identical scores from saved predictions; parameter counts and training budgets are reported. A single failed LoRA recipe is evidence about that recipe, not proof that the model cannot adapt. ## P3 — Train the no-ID local floor adapter The primary method is a short-window causal encoder over recent mixed audio and per-frame anonymous visible-person sets. It uses no participant-ID embedding or cross-time track state. Compare it with: 1. Recent local audio only. 2. Global/full-frame visual pooling. 3. A parameter- and history-matched temporal branch. 4. Time-shifted local vision. 5. Removed local vision. 6. A same-rate control if the local path runs faster than 5 Hz. Keep the dense EgoSpeak wearer/others target as the primary task. Target of speech is analysis-only and never model input. Use ``dual-rate'' only if the local input/update rate differs explicitly and defeats the same-rate control. Unit-test variable person count, empty sets, padding, person-set permutation, source/gap resets, and strict causal cutoffs. ## P4 — Consider track continuity only after the no-ID method wins Only if a track-aware candidate then beats the no-ID method on training-side data, evaluate one frozen checkpoint with: - correct person tracks; - clip-consistent global renaming, which must be invariant; - deliberately broken cross-time identity with unchanged per-frame crops; - time-shifted tracks with unchanged audio; - removed visual features; - fixed-rate ID switch, box dropout, and fragmentation; - visibility-conditioned subsets. The separately trained no-ID model belongs in the main ablation table. Do not retrain test-time counterfactuals. ## P5 — Statistics and evidence - [ ] Three seeds, mean ± sample standard deviation. - [ ] Paired cluster bootstrap by session/conversation block for 95% intervals. - [ ] Operating points at wearer-onset recall 0.7, 0.8, and 0.9; headline 0.8. - [ ] Fixed-horizon entry/INT event AP, recall-matched hard-negative opportunity FPR, subtype FPR, and original ten-horizon dense AP/mAP. - [ ] Treat one-to-one event matching and signed latency as secondary; report them only after freezing the online threshold, persistence, refractory period, matching interval, and competing-risk rule. - [ ] Error strata: visibility, number of visible people, overlap, offscreen activity, and transition proxy. Add track age/fragmentation only if a track-aware method is selected. - [ ] Ego4D AVD coverage audit on the exact EgoSpeak split before claiming the same multi-other analysis. - [ ] Name the causal box source and its limitations. Add separate provided-track/online-tracker rows only if tracking enters the selected method. Qualitative cases follow a frozen selection rule and include the largest paired improvement, a median case, a failure, and one preserved true wearer onset. Examples explain rates; they never replace them. ## Paper assembly order 1. Freeze and audit the event protocol. 2. Audit the Qwen2.5-Omni-3B readout and matched PEFT baseline. 3. Complete the frozen/PEFT/audio/matched-temporal/local-AV matrix. 4. Run correct/time-shift/remove-vision controls and the optional 7B scaling row. 5. Run the Qwen refresh-rate control and the scoped MiniCPM-o streaming/cache diagnostic; admit the 5-Hz MiniCPM-o row only after equivalence and leakage audits. 6. Consider track continuity only if the no-ID method already passes. 7. Produce one confirmatory event table and one mechanism-ablation table. 8. Draw one compact final system figure; remove rejected methods from the main narrative. 9. Replace every visible TODO and verify the ICASSP 2027 kit/page limit. ## Stop/go decisions - **Claim boundary:** with Qwen-only evidence, describe a Qwen2.5-Omni case study and the tested adaptation mechanism; do not generalize to all Omni models. - **Streaming boundary:** call native MiniCPM-o 1-Hz plus causal hold a held-state baseline, not native 5-Hz inference; a 5-Hz cache result exists only after cached/full-prefix equivalence and future-input invariance pass. - **Audio-local reframe:** local audio improves but all visual variants fail; claim a fine-grained acoustic readout bottleneck, not social visual reasoning. - **Track-aware method:** correct continuity beats pooled vision, temporal capacity, no-ID/reset, broken continuity, and time-shifted controls at matched recall without worse onset/yield behavior. - **Stop the adapter:** aggregate mAP rises but multi-other false entries do not fall, or legitimate onset/yield behavior degrades.